Precision sealing
for Genset power
Your Generator Set Must Remain Ready for Operation, Even After Months of Inactivity
A generator set must be ready to start at any time, including after extended periods without operation. The fuel and cooling circuits that support it must remain perfectly sealed, as even a minor fuel leak can prevent a successful emergency start.
A seal that shrinks or loses its elasticity during prolonged inactivity can compromise sealing performance without any visible warning signs, putting the reliability of your entire backup power system at risk.
Find your solution
No products match your search
Our Sealing Solutions
O-Rings
O-rings are used throughout the fixed sealing interfaces of your generator set, from fuel circuit connections to cooling system housings. Their circular design minimizes the risk of installation errors, while the controlled deformation of the seal cross-section under compression optimizes sealing performance.
We offer a wide range of elastomer materials and hardness grades to match the compression requirements and operating conditions of your assembly.
High-Performance Compounds
The long-term performance of a seal depends largely on the compound from which it is made, particularly during extended periods of inactivity.
We provide high-performance elastomer compounds specifically developed for critical applications operating under high pressure and elevated temperatures. Their resistance to ageing and material shrinkage helps minimize the risk of leakage, a common cause of startup failures after prolonged shutdown periods.